Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry
查看参考文献25篇
文摘
|
A simple, rapid, and sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the simultaneous determination of two fatty acids, methyl hexadecanoate (MH) and methyl stearate (MS), to allow the evaluation of packaging-drug compatibility. The two migrants were quantified in selective ion-monitoring (SIM) mode, with limits of detection (LOD) of 0.0030 μg/mL and 0.0121 μg/mL. Linear calibration curves for MH and MS were obtained in the concentration ranges of 0.1011–5.0570 μg/mL and 0.2015–10.0740 μg/mL, respectively. The developed method was successfully applied to estimate the safety of the injection of recombinant antitumor-antivirus protein (RAAP). The results showed that the possible maximum daily intake was 3.0 ng and 12.1 ng for MH and MS, respectively. As these values were both below the permitted daily exposure, the migrants can be considered as having low safety risk and do not affect the quality of the injection. |
来源
|
Journal of Pharmaceutical Analysis
,2019,9(3):178-184 【核心库】
|
DOI
|
10.1016/j.jpha.2018.10.002
|
关键词
|
Compatibility
;
Rubber stoppers
;
Injection
;
Fatty acids
;
GC-MS
|
地址
|
1.
School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016
2.
Anshan Institute for Food and Drug Control, Anshan, 114006
3.
Shenyang Wellwolf Pharmaceutical Science and Technology Co., Ltd, Shenyang, 110022
|
语种
|
英文 |
文献类型
|
研究性论文 |
ISSN
|
2095-1779 |
学科
|
化学;药学 |
文献收藏号
|
CSCD:6521749
|
参考文献 共
25
共2页
|
1.
Xie L G. Determination of fatty acids in rubber stoppers.
Plast. Sci. Technol,2014,42:102-104
|
CSCD被引
1
次
|
|
|
|
2.
Boven K. The increased incidence of pure red cell aplasia with an Eprex formulation in uncoated rubber stopper syringes.
Kidney Int,2017,67:2346-2353
|
CSCD被引
5
次
|
|
|
|
3.
Sharma B. Technical investigation into the cause of the increased incidence of anti-body-mediated pure red cell aplasia associated with EPREXs.
Eur. J. Hosp. Pharm,2004,5:86-91
|
CSCD被引
2
次
|
|
|
|
4.
Jenke D. Evaluation of the chemical compatibility of plastic contact materials and pharmaceutical products; safety considerations related to extractables and leachables.
J. Pharm. Sci,2007,96:2566-2581
|
CSCD被引
3
次
|
|
|
|
5.
Feng J. Determination of antiosidant-BHT and vulcanizing agent extractable sulphur in medicinal butyl rubber.
Chin. J. Pharm. Anal,2017,37:702-706
|
CSCD被引
2
次
|
|
|
|
6.
Xiao B M. Development and validation of HPLC methods for the determination of potential extractables from elastomeric stoppers in the presence of a complex surfactant vehicle used in the preparation of parenteral drug products.
J. Pharm. Biomed. Anal,2017,43:558-565
|
CSCD被引
5
次
|
|
|
|
7.
Zhang F. Structural identification of extractables from rubber cloures used for pre-filled semisolid drug applicator by chromatography, mass spectrometry, and organic systhesis.
J. Pharm. Biomed. Anal,2004,34:841-849
|
CSCD被引
6
次
|
|
|
|
8.
Stults C L. Evaluation of extractables in processed and unprocessed polymer materials used for pharmaceutical applications.
AAPS PharmSciTech,2015,16:150-164
|
CSCD被引
2
次
|
|
|
|
9.
Ma Y N. Interpretation of the guideline of compatibility study of pharmaceutical products and packaging materials the assessment of experimental data.
Chin. J. New Drugs,2014,28:940-943
|
CSCD被引
1
次
|
|
|
|
10.
Qian Q J. Study on compatibility in between packaging materials and Haemophilus influenzae type b conjugate vaccine.
Prog. Microbiol. Immunol,2012,40:42-46
|
CSCD被引
1
次
|
|
|
|
11.
Corredor C C. Comprehensive determination of extractables from five different brands of stoppers used for injectable products.
PDA J. Pharm. Sci. Technol,2009,63:527-536
|
CSCD被引
1
次
|
|
|
|
12.
Pu X C. HPLC determination for migration of antioxidant 1076 from rubber stopper to micafungin sodium injection.
Chin. J. Pharm. Anal,2017,37:1298-1303
|
CSCD被引
2
次
|
|
|
|
13.
Pan X E. Evaluating compatibility between propofol injection and neutral borosilicate glass ampoule.
China Meas. Test,2017,43:45-48
|
CSCD被引
1
次
|
|
|
|
14.
Zhang G X.
Compatibility Studies on Recombinant Human Erythropoietin Injection with Prefillable Syringes,2016
|
CSCD被引
1
次
|
|
|
|
15.
Zhang J H. The application of non-PVC coextruded film in the medical infusion packs.
China Packag. Ind,2002,2:23-24
|
CSCD被引
1
次
|
|
|
|
16.
Zhao X. The analysis of volatile substances of butyl rubber closures.
Chin. J. Pharm. Anal,2006,26:315-318
|
CSCD被引
2
次
|
|
|
|
17.
Zhao X.
Study on the Compatibility between Butyl Rubber Cloures and Ceftriaxone Sodium,2006
|
CSCD被引
1
次
|
|
|
|
18.
Haverkamp J B. Contamination of semi-solid dosage forms by leachables from aluminium tubes.
Eur. J. Pharm. Biopharm,2008,70:921-928
|
CSCD被引
1
次
|
|
|
|
19.
Zhao X. Consideration and suggestion to estimate the compatibility between rubber closures and drugs.
Chin. Pharm. Aff,2007,21:810-812
|
CSCD被引
1
次
|
|
|
|
20.
Xue Z R. Research on the compatibility of medical grade halogenated butyl rubber stopper.
Strait Pharm. J,2017,29:8-10
|
CSCD被引
2
次
|
|
|
|
|