Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry

查看参考文献25篇

文摘 A simple, rapid, and sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the simultaneous determination of two fatty acids, methyl hexadecanoate (MH) and methyl stearate (MS), to allow the evaluation of packaging-drug compatibility. The two migrants were quantified in selective ion-monitoring (SIM) mode, with limits of detection (LOD) of 0.0030 μg/mL and 0.0121 μg/mL. Linear calibration curves for MH and MS were obtained in the concentration ranges of 0.1011–5.0570 μg/mL and 0.2015–10.0740 μg/mL, respectively. The developed method was successfully applied to estimate the safety of the injection of recombinant antitumor-antivirus protein (RAAP). The results showed that the possible maximum daily intake was 3.0 ng and 12.1 ng for MH and MS, respectively. As these values were both below the permitted daily exposure, the migrants can be considered as having low safety risk and do not affect the quality of the injection.
来源 Journal of Pharmaceutical Analysis ,2019,9(3):178-184 【核心库】
DOI 10.1016/j.jpha.2018.10.002
关键词 Compatibility ; Rubber stoppers ; Injection ; Fatty acids ; GC-MS
地址

1. School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016  

2. Anshan Institute for Food and Drug Control, Anshan, 114006  

3. Shenyang Wellwolf Pharmaceutical Science and Technology Co., Ltd, Shenyang, 110022

语种 英文
文献类型 研究性论文
ISSN 2095-1779
学科 化学;药学
文献收藏号 CSCD:6521749

参考文献 共 25 共2页

1.  Xie L G. Determination of fatty acids in rubber stoppers. Plast. Sci. Technol,2014,42:102-104 CSCD被引 1    
2.  Boven K. The increased incidence of pure red cell aplasia with an Eprex formulation in uncoated rubber stopper syringes. Kidney Int,2017,67:2346-2353 CSCD被引 5    
3.  Sharma B. Technical investigation into the cause of the increased incidence of anti-body-mediated pure red cell aplasia associated with EPREXs. Eur. J. Hosp. Pharm,2004,5:86-91 CSCD被引 2    
4.  Jenke D. Evaluation of the chemical compatibility of plastic contact materials and pharmaceutical products; safety considerations related to extractables and leachables. J. Pharm. Sci,2007,96:2566-2581 CSCD被引 3    
5.  Feng J. Determination of antiosidant-BHT and vulcanizing agent extractable sulphur in medicinal butyl rubber. Chin. J. Pharm. Anal,2017,37:702-706 CSCD被引 2    
6.  Xiao B M. Development and validation of HPLC methods for the determination of potential extractables from elastomeric stoppers in the presence of a complex surfactant vehicle used in the preparation of parenteral drug products. J. Pharm. Biomed. Anal,2017,43:558-565 CSCD被引 5    
7.  Zhang F. Structural identification of extractables from rubber cloures used for pre-filled semisolid drug applicator by chromatography, mass spectrometry, and organic systhesis. J. Pharm. Biomed. Anal,2004,34:841-849 CSCD被引 6    
8.  Stults C L. Evaluation of extractables in processed and unprocessed polymer materials used for pharmaceutical applications. AAPS PharmSciTech,2015,16:150-164 CSCD被引 2    
9.  Ma Y N. Interpretation of the guideline of compatibility study of pharmaceutical products and packaging materials the assessment of experimental data. Chin. J. New Drugs,2014,28:940-943 CSCD被引 1    
10.  Qian Q J. Study on compatibility in between packaging materials and Haemophilus influenzae type b conjugate vaccine. Prog. Microbiol. Immunol,2012,40:42-46 CSCD被引 1    
11.  Corredor C C. Comprehensive determination of extractables from five different brands of stoppers used for injectable products. PDA J. Pharm. Sci. Technol,2009,63:527-536 CSCD被引 1    
12.  Pu X C. HPLC determination for migration of antioxidant 1076 from rubber stopper to micafungin sodium injection. Chin. J. Pharm. Anal,2017,37:1298-1303 CSCD被引 2    
13.  Pan X E. Evaluating compatibility between propofol injection and neutral borosilicate glass ampoule. China Meas. Test,2017,43:45-48 CSCD被引 1    
14.  Zhang G X. Compatibility Studies on Recombinant Human Erythropoietin Injection with Prefillable Syringes,2016 CSCD被引 1    
15.  Zhang J H. The application of non-PVC coextruded film in the medical infusion packs. China Packag. Ind,2002,2:23-24 CSCD被引 1    
16.  Zhao X. The analysis of volatile substances of butyl rubber closures. Chin. J. Pharm. Anal,2006,26:315-318 CSCD被引 2    
17.  Zhao X. Study on the Compatibility between Butyl Rubber Cloures and Ceftriaxone Sodium,2006 CSCD被引 1    
18.  Haverkamp J B. Contamination of semi-solid dosage forms by leachables from aluminium tubes. Eur. J. Pharm. Biopharm,2008,70:921-928 CSCD被引 1    
19.  Zhao X. Consideration and suggestion to estimate the compatibility between rubber closures and drugs. Chin. Pharm. Aff,2007,21:810-812 CSCD被引 1    
20.  Xue Z R. Research on the compatibility of medical grade halogenated butyl rubber stopper. Strait Pharm. J,2017,29:8-10 CSCD被引 2    
引证文献 1

1 董贤宝 卧室灰尘中895种半挥发性有机物的存在水平及健康风险 生态毒理学报,2023,18(1):101-113
CSCD被引 0 次

显示所有1篇文献

论文科学数据集
PlumX Metrics
相关文献

 作者相关
 关键词相关
 参考文献相关

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心
地址:北京中关村北四环西路33号 邮政编码:100190 联系电话:(010)82627496 E-mail:cscd@mail.las.ac.cn 京ICP备05002861号-4 | 京公网安备11010802043238号