帮助 关于我们

返回检索结果

快速空间测角系统中偏振像差的分析与研究
Analysis and research of polarization aberration in rapid space angle measuring system

查看参考文献30篇

李春艳 1 *   陆卫国 2   乔琳 1  
文摘 快速空间测角系统需要在一定的平移范围内均能实现测量功能,这就要求光束在接收单元具有一定的覆盖面积.受器件尺寸所限,选择对入射光束进行扩束,然而非正入射光经过系统会产生偏振态变化,存在偏振像差,引起测量误差.本文通过采用偏振光线追迹的方法,结合电磁场的边界条件,对快速空间测角系统中一定方位及入射角范围内的光束通过偏振棱镜后出射光束的偏振态变化与分布进行了理论研究及仿真分析;并通过搭建实验平台,利用平移接收单元来模拟不同的入射方位及角度变化.根据实验值与仿真结果的对比分析,得出在方位角为0°时,测量误差较小,在方位角为90°时,测量误差最大,且随平移距离(即入射角)的增大,测角误差增大.验证了偏振像差的存在对系统测角带来的影响及理论分析的正确性,并提出了改进措施.所得研究结果对优化系统结构并进一步提高系统性能具有一定的指导意义.
其他语种文摘 The precise angle measurement and transmission technology have been widely used in the precision measurement,aerospace,military,biomedicine and other devices,which are based on the polarized light and magneto-optical modulation.This method has the characteristics of no rigid connection required,long distance transmission,high precision,etc.However,the azimuth information measurement method needs the assistance of complex servo tracking system according to the orthogonal extinction principle of polarization prism,meanwhile,the measurement time is longer,which reduces reliability and reaction sensitivity of the system.In order to improve the measurement accuracy and fast response capability of the system,a fast space goniometry method is proposed through the Wollaston prism polarizing beam splitter,with which the azimuth is directly calculated according to the two light intensities.The measurement time can be shortened,and the accuracy is improved by the use of magneto-optical modulation technology.The rapid space angle measuring system needs to realize the measurement function in a certain translation range,which requires the beam to have a certain coverage area in the receiving unit.However,the system is limited by size and volume of the device;we can only choose to expand the incident beam.Therefore,when the beam is incident onto the receiving unit,some incident angle and azimuth,that is,non-vertical incidence will be produced.However,the polarization of the non-vertically incident light passing through the system will change and polarization aberration exists,which will lead to measurement error.In this paper,the beam passes through the polarizing prism in a certain range of azimuths and incident angles,and the polarized light tracing method and the boundary condition of the electromagnetic field are used to study and simulate the polarization change and distribution of the outgoing beam.The changes of different incident azimuths and angles can be simulated through the translation of receiving unit,and the azimuths can be measured indirectly by using self-collimation theodolite and right angle prism.By comparing the measured azimuths under the translational and centering conditions,the influence of polarization aberration on the angle measuring system and the correctness of the theoretical analysis are verified.It is concluded that when the azimuth angle is 0°,the measurement error is small;when the azimuth is 90°,the measurement error is largest,meanwhile the measurement error will increase with the translation distance becoming longer(i.e.,the incident angle).According to the comparison between the experimental data and the simulation results,the existing problems are pointed out,and the corresponding improvement measures are proposed.The results of this work have some significance in guiding the optimization of the system structure,and the further improvement inthe performance of the system.
来源 物理学报 ,2018,67(3):030703-1-030703-8 【核心库】
DOI 10.7498/aps.67.20171702
关键词 偏振光 ; 方位角测量 ; 偏振像差 ; Glan-Taylor棱镜
地址

1. 西安邮电大学电子工程学院光电子技术系, 西安, 710121  

2. 中国科学院西安光学精密机械研究所, 西安, 710119

语种 中文
文献类型 研究性论文
ISSN 1000-3290
学科 电子技术、通信技术
基金 陕西省自然科学基金 ;  陕西省教育厅项目 ;  国家自然科学基金
文献收藏号 CSCD:6192343

参考文献 共 30 共2页

1.  董晓娜. 利用磁光调制实现方位角垂直传递. 光子学报,2001,30:1389 CSCD被引 23    
2.  申小军. 一种无机械连接的方位测量同步系统. 光子学报,2001,30:892 CSCD被引 15    
3.  吴易明. 博士学位论文,2009 CSCD被引 1    
4.  吴易明. 基于偏振光的精密角度测量及传递技术. 红外与激光工程,2008,37:525 CSCD被引 18    
5.  杨志勇. 方波磁光调制测量在无机械连接的设备间方位传递中的应用. 光学学报,2012,32:1212006 CSCD被引 8    
6.  杨志勇. 光学学报,2015,25:s112003 CSCD被引 2    
7.  杨志勇. 利用原始光强信号实现空间方位失调角高精度传递新方法. 光学学报,2012,32:0112006 CSCD被引 8    
8.  杨志勇. 基于正弦波磁光调制的方位失调角精确测量方法. 光学学报,2012,32:1012001 CSCD被引 7    
9.  杨志勇. 光学,2012,20:692 CSCD被引 1    
10.  沈骁. 光电子,2014,25:1535 CSCD被引 1    
11.  杨志勇. 基于磁光调制偏振光的空间方位失调角高精度测量新方法. 光学学报,2011,31:1112008 CSCD被引 9    
12.  陆卫国. 利用偏振光实现空间方位角的快速测量. 光学·精密工程,2013,21:539 CSCD被引 12    
13.  陆卫国. 方波调制消除Wollaston棱镜非线性系数对空间测角的影响. 红外与激光工程,2014,43:2198 CSCD被引 4    
14.  陆卫国. 博士学位论文,2013 CSCD被引 1    
15.  杨宇飞. 光子学报,2016,36:1106003 CSCD被引 1    
16.  李旸晖. 光学薄膜诱导偏振像差对大数值孔径光学系统聚焦特性的影响. 物理学报,2015,64:154214 CSCD被引 4    
17.  Yun G. Opt. Lett,2011,36:4062 CSCD被引 4    
18.  许洁. 基于渥拉斯顿棱镜的单路实时偏振成像系统设计. 物理学报,2016,65:134201 CSCD被引 4    
19.  Lam W S T. Appl. Opt,2015,54:3236 CSCD被引 4    
20.  吴海英. 基于组合Wollaston棱镜成像光谱仪的视场扩大原理分析. 物理学报,2009,58:930 CSCD被引 7    
引证文献 2

1 郝安庆 用于冷原子制备的激光扩束准直器的研制 光子学报,2020,49(3):0314002
CSCD被引 0 次

2 蔡伟 基于保偏光纤的非通视方位传递技术 光学学报,2020,40(15):1512001
CSCD被引 2

显示所有2篇文献

论文科学数据集
PlumX Metrics
相关文献

 作者相关
 关键词相关
 参考文献相关

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心
地址:北京中关村北四环西路33号 邮政编码:100190 联系电话:(010)82627496 E-mail:cscd@mail.las.ac.cn 京ICP备05002861号-4 | 京公网安备11010802043238号