前置反硝化-高负荷地下渗滤系统深度脱氮研究
Study on Advanced Nitrogen Removal by High Hydraulic Loading Subsurface Infiltration System with Pre-denitrification
查看参考文献25篇
文摘
|
针对高负荷地下渗滤系统TN去除率低的问题,研究将渗滤出水回流与原污水混合,进入前置反硝化单元。结果表明,当回流体积比分别为0.5:1、1:1和2:1时,系统对NH_4~+-N的去除率高于92%,且出水NH_4~+-N的质量浓度低于0.5 mg/L;前置反硝化单元对NO_3~--N去除率分别为91.0%、83.0%和64.2%,而系统对TN去除率仅为18.6%、31.2%和30.8%。在回流体积比为2:1时,将原污水COD/ρ(TN)调为6,以与常规生活污水C/N相同,此时反硝化单元的NO_3~--N去除率升至95.2%,而系统TN去除率升至57.1%,且出水TN的质量浓度低于15 mg/L。因此,如果采用该组合工艺处理常规生活污水(COD/ρ(TN)大于6),可使其最终出水TN和NH_4~+-N含量达到更严格的排放标准。 |
其他语种文摘
|
Aimed at promoting the total nitrogen removal of high hydraulic loading subsurface infiltration system(HLS),the pre-denitrification device was employed to treat the HLS effluent mixed with raw sewage.The results showed that the removal rates of NH_4~+-N were over 92% and the mass concentration of NH_4~+-N in effluent was lower than 0.5 mg/L no matter the reflux volume ratios were 0.5:1,1:1 and 2:1,while the NO_3~--N removal rates were 91.0%,83.0%,and 64.2% respectively in the pre-denitrification device,and the TN removal rates were only 18.6%,31.2%,and 30.8% respectively in the combined system.The COD/ρ(TN)of the raw sewage was adjusted to 6 same as the ordinary sewage when the reflux volume ratio was set at 2:1,the removal rate of NO_3~--N in pre-denitrification device was increased to 95.2% and TN in the whole system was increased to 57.1%,and the mass concentration of TN in effluent was less than 15 mg/L.Therefore,the TN and NO_3~--N content of treated effluent from the combined system could meet the stricter discharge standard when it was applied to treat the sewage with higher COD/ρ(TN)(≥6). |
来源
|
水处理技术
,2018,44(10):89-93 【核心库】
|
DOI
|
10.16796/j.cnki.1000-3770.2018.10.019
|
关键词
|
高负荷
;
地下渗滤系统
;
前置反硝化
;
回流比
;
碳氮比
|
地址
|
1.
中国科学院广州地球化学研究所, 中国科学院矿物学与成矿学重点实验室;;广东省矿物物理与材料研究开发重点实验室, 广东, 广州, 510640
2.
中国科学院大学, 北京, 100049
|
语种
|
中文 |
文献类型
|
研究性论文 |
ISSN
|
1000-3770 |
学科
|
行业污染、废物处理与综合利用 |
基金
|
广东省科技计划项目
;
广东省广州市科技计划项目
;
中国科学院广州地球化学研究所“一三五”规划项目
|
文献收藏号
|
CSCD:6381666
|
参考文献 共
25
共2页
|
1.
马琳. 我国农村生活污水组合处理技术研究进展.
水处理技术,2014,40(10):1-5
|
CSCD被引
18
次
|
|
|
|
2.
Shi J B. Simultaneous determination of methylmercury and ethylmercury in rice by capillary gas chromatography coupled on-line with atomic fluorescence spectrometry.
Journal of Aoac International,2005,88(2):665-669
|
CSCD被引
8
次
|
|
|
|
3.
井柳新. 农业源水污染物削减技术探讨.
环境污染与防治,2015,37(3):45-47
|
CSCD被引
1
次
|
|
|
|
4.
曾丽璇. 新型人工湿地生态填料净化生活污水的试验研究.
环境污染与防治,2012,34(9):24-27
|
CSCD被引
5
次
|
|
|
|
5.
张曼雪. 农村生活污水处理技术研究进展.
水处理技术,2017,43(6):5-10
|
CSCD被引
19
次
|
|
|
|
6.
.
水污染物综合排放标准:DB 11/301-2013
|
CSCD被引
1
次
|
|
|
|
7.
Hu Y. High rate nitrogen removal in an alum sludge-based intermittent aeration constructed wetland.
Environmental Science & Technology,2012,46(8):4583-4590
|
CSCD被引
23
次
|
|
|
|
8.
Zhang J. Nitrogen removal enhanced by intermittent operation in a subsurface wastewater infiltration system.
Ecological Engineering,2005,25(4):419-428
|
CSCD被引
34
次
|
|
|
|
9.
Yang Y. Effect of hydraulic loading rate on pollutant removal efficiency in subsurface infiltration system under intermittent operation and micro-power aeration.
Bioresource Technology,2016,205:174-182
|
CSCD被引
10
次
|
|
|
|
10.
Pan J. Characteristics of microbial populations and enzyme activities in non-shunt and shunt subsurface wastewater infiltration systems during nitrogen removal.
Ecological Engineering,2013,61(61):127-132
|
CSCD被引
8
次
|
|
|
|
11.
潘晶. 污水地下渗滤系统强化脱氮试验研究.
中国环境科学,2011,31(9):1456-1460
|
CSCD被引
9
次
|
|
|
|
12.
Zhao W. Advanced nitrogen and phosphorus removal in the pre-denitrification anaerobic/anoxic/aerobic nitrification sequence batch reactor (pre-A2NSBR) treating low carbon/nitrogen (C/N) wastewater.
Chemical Engineering Journal,2016,302:296-304
|
CSCD被引
22
次
|
|
|
|
13.
王琪. 改进倒置A~2/O工艺处理生活污水试验研究.
环境污染与防治,2007,29(5):361-362
|
CSCD被引
4
次
|
|
|
|
14.
钟永英. 污水处理后出水中硝酸盐氮的检测及其意义.
材料研究与应用,2009,3(3):213-215
|
CSCD被引
3
次
|
|
|
|
15.
国家环境保护总局《水和废水监测分析方法》编委会.
水和废水监测分析方法. (4版),2002:271-274
|
CSCD被引
2
次
|
|
|
|
16.
.
水质氨氮的测定纳氏试剂分光光度法:HJ 535-2009
|
CSCD被引
29
次
|
|
|
|
17.
贾国珍. “微波消解COD测定仪”在水环境监测中的应用与探讨.
东北水利水电,2001,19(5):48-50
|
CSCD被引
9
次
|
|
|
|
18.
.
城镇污水处理厂污染物排放标准:GB18918-2002
|
CSCD被引
6
次
|
|
|
|
19.
Kantawanichkul S. Nitrogen removal by a combined subsurface vertical down-flow and up-flow constructed wetland system.
Wastewater Treatment, Plant Dynamics and Management in Constructed and Natural Wetlands,2008:161-170
|
CSCD被引
1
次
|
|
|
|
20.
苏功平. 复合生物滤池+ 潜流人工湿地组合工艺处理农村生活污水.
环境工程学报,2016,10(2):775-780
|
CSCD被引
11
次
|
|
|
|
|