帮助 关于我们

返回检索结果

太阳衰减屏的设计及性能评估
Design and performance evaluation of solar attenuation screen

查看参考文献15篇

许和鱼 1,2,3   张黎明 2,3   司孝龙 2,3   徐伟伟 2,3   黄文薪 2,3   刘辉 1,2,3   汪伟 1,2,3   乔延利 2,3  
文摘 基于双太阳漫射板星上定标系统,建立了定标漫射板双向反射分布函数(BRDF)衰减监测模型,介绍了用于衰减入射太阳光通量的太阳衰减屏的结构设计.衰减屏透过率是影响星上定标精度的关键参数之一,需要在发射前精确测量.在实验室利用衰减屏透过率测量系统对其进行多次重复测量,结果表明衰减屏在测试角度范围内透过率为13.8%,测试不确定度优于0.54%(K为2),满足星上定标需求.测试结果可用于建立地面数据库,为后期星上定标提供数据支撑,对保证长期星上定标精度有重要意义.
其他语种文摘 Based on double solar diffusers on-board calibration system,a bidirectional reflectance distribution function (BRDF) attenuation monitoring model of calibration diffuser is established, and the structure design of solar attenuation screen for attenuating the incident sunlight flux is introduced. The attenuation screen transmittance is one of the key parameters that affect on-board calibration accuracy, and it need to be measured accurately before launch. It is measured repeatedly with the attenuation screen transmittance measurement system. Results show that the attenuation screen transmittance is 13.8% within the test angle range, and the test uncertainty is better than 0.54% (K is 2),which satisfies the requirements of on-board calibration. Test results can be used to establish the ground database,and it can provide data support for the later satellite calibration, which is of great significance to ensure the long-term on-board calibration accuracy.
来源 量子电子学报 ,2018,35(3):359-365 【扩展库】
DOI 10.3969/j.issn.1007-5461.2018.03.016
关键词 遥感 ; 星上定标 ; 太阳衰减屏 ; 衰减屏透过率 ; 不确定度
地址

1. 中国科学技术大学环境科学与光电技术学院, 安徽, 合肥, 230026  

2. 中国科学院安徽光学精密机械研究所, 安徽, 合肥, 230031  

3. 中国科学院通用光学定标与表征技术重点实验室, 中国科学院通用光学定标与表征技术重点实验室, 安徽, 合肥, 230031

语种 中文
文献类型 研究性论文
ISSN 1007-5461
学科 物理学
基金 国家自然科学基金 ;  中国科学院重点实验室基金
文献收藏号 CSCD:6246588

参考文献 共 15 共1页

1.  Yang Benyong. Characteristic measurement of diffuser panel used for onboard calibration for satellite optical sensors. 光学精密工程,2009,17(8):1851-1858 被引 1    
2.  Li Mengfan. Study of the response characteristic of ratioing radiometer. 光学学报,2016,36(2):0212005 被引 1    
3.  Huang Wenxin. Theory and precision maintenance method of on-orbit reflectance calibration. 光学学报,2016,36(6):1-8 被引 1    
4.  Xiong X. Performance of Terra MODIS solar diffuser and solar diffuser stability monitor. Proceedings of SPIE. 5882,2005:58820S 被引 1    
5.  Carina O. Spectralon diffuser calibration for MERIS. Proceedings of SPIE. 3221,1997:63-74 被引 1    
6.  Justic C O. The moderate resolution imaging spectroradiometer (MODIS):Land remote sensing for global change research. IEEE Transactions on Geo science and Remote Sensing,1998,36(4):1228-1249 被引 2    
7.  Zha Peng. Research on spaceborne radiant calibration technology of space cameral. 红外,2006,27(3):32-38 被引 1    
8.  Yang Benyong. Space stability measurement and analysis of diffuser panel used for on-board calibration for satellite optical sensors. 中国激光,2009,36(11):3026-3030 被引 1    
9.  Wang Xianhua. Study of bidirectional reflectance calibration based on varied grey scale panels. 光电子技术与信息,1991,11(5):10-15 被引 1    
10.  Lei Ning. Determination of the SNPP VIIRS SDSM screen transmittance from both yaw maneuver and regular on-orbit data. SPIE. 9218(3),2014:1-12 被引 1    
11.  Waluschka E. MODIS solar calibration transmission screen modeling. SPIE. 5652,2004:189-199 被引 1    
12.  Waluschka E. Modeling studies of the MODIS solar diffuser attenuation screen and comparison with on-orbit measurements. SPIE. 5552,2004:342-353 被引 1    
13.  Chen Hongyao. High accuracy gonioreflectometer for solar diffuser spectral BRDF measurement. 大气与环境光学学报,2014,1(9):72-80 被引 1    
14.  Li Junlin. Development of BRDF absolute measuring device. 光学学报,2014,34(5):1-8 被引 1    
15.  Li Junlin. BRDF device based on six-axis robot. 光学精密工程,2014,22(11):2983-2989 被引 1    
引证文献 2

1 许权 基于BM3803的步进电机控制系统设计与实现 大气与环境光学学报,2019,14(6):463-473
被引 0 次

2 黄文薪 太阳衰减屏光衰减非均匀性对星上定标的影响 光学学报,2020,40(4):0429002
被引 0 次

显示所有2篇文献

论文科学数据集
PlumX Metrics
相关文献

 作者相关
 关键词相关
 参考文献相关

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心
地址:北京中关村北四环西路33号 邮政编码:100190 联系电话:(010)82627496 E-mail:cscd@mail.las.ac.cn 京ICP备05002861号-4 | 京公网安备11010802043238号