电机电流信号特征分析(MCSA)是诊断鼠笼电机早期转子断条故障的常用方法。当电机在时变转速状态下运行时,转速和滑差连续变化,定子电流表现为非平稳信号,MCSA不再有效。本文提出一种鼠笼电机时变转速运行状态下的早期转子断条故障诊断新方法。该方法的核心是对定子电流Park矢量模平方信号作离散小波变换,然后根据转子断条故障特征频率2sf在转速连续变化期间的波形演变图谱以及小波能量变化判断故障发生与否。在3kW电机实验台上对所提出的方法进行实验验证,实验结果证实了所提方法的有效性。 |
其他语种文摘
|
Motor current signature analysis (MCSA) has been successfully used in squirrel cage motor for the diagnosis of incipient broken rotor bar defect. However, when the motor operates in time-varying rotating speed condition, the method fails as the rotating speed and slip vary, thus, the stator current is characterized as a non-stationary signal. This paper proposes a novel fault diagnosis method for the incipient broken rotor bar of squirrel cage motor in time-varying rotating speed operation condition. The core of the method is to conduct discrete wavelet transformation on the 3 phase stator current Park ' s vector modulus square signal; and according to the waveform evolution spectrum of broken rotor bar fault frequency 2sf characteristic pattern and the wavelet energy changing during the speed continuous variation, it is judged if the broken rotor bar defect occurs. The experiment verification was performed on a 3kw motor experiment test bench; the experiment results prove the effectiveness of the proposed method. |
来源
|
仪器仪表学报
,2016,37(4):834-842 【核心库】
|
关键词
|
鼠笼电机
;
转子断条
;
Park矢量模
;
离散小波变换
;
故障诊断
|
地址
|
1.
沈阳工业大学信息科学与工程学院, 沈阳, 110870
2.
辽宁科技大学电子与信息工程学院, 鞍山, 114051
3.
中国科学院沈阳自动化研究所, 沈阳, 110016
|
语种
|
中文 |
文献类型
|
研究性论文 |
ISSN
|
0254-3087 |
学科
|
机械、仪表工业 |
基金
|
中国科学院重点部署项目
|
文献收藏号
|
CSCD:5708765
|
参考文献 共
16
共1页
|
1.
Ostojic P. Advanced motor monitoring and diagnostics.
IEEE Pulp and Paper Industry Technical Conference,2014:197-206
|
被引
1
次
|
|
|
|
2.
Picazo-Rodenas M J. Combination of Noninvasive approaches for general assessment of induction motors.
IEEE Transactions on Industry Applications,2015,51(3):2172-2180
|
被引
2
次
|
|
|
|
3.
Singh A. A review of induction motor fault modeling.
Electric Power Systems Research,2016,13(3):191-197
|
被引
1
次
|
|
|
|
4.
李晓晖. 基于一维盲源分离的滚动轴承故障诊断.
电子测量与仪器学报,2013,27(6):535-542
|
被引
10
次
|
|
|
|
5.
李志农. 基于经验小波变换的机械故障诊断方法研究.
仪器仪表学报,2014,35(11):2423-2432
|
被引
84
次
|
|
|
|
6.
贾朱植. 鼠笼电机转子断条故障的定子电流信号平方解调分析诊断方法.
仪器仪表学报,2015,36(9):2097-2103
|
被引
4
次
|
|
|
|
7.
谢苗. 基于改进型ANFIS的矿用空压机故障诊断系统.
电子测量与仪器学报,2015,29(4):500-507
|
被引
2
次
|
|
|
|
8.
李红梅. 永磁同步电机参数辨识研究综述.
电子测量与仪器学报,2015,29(5):638-647
|
被引
19
次
|
|
|
|
9.
Henao H. Trends in fault diagnosis for electrical machines : a review of diagnostic techniques.
IEEE Industrial Electronics Magazine,2014,8(2):31-42
|
被引
9
次
|
|
|
|
10.
Eftekhari M. Online detection of induction motors stator winding short-circuit faults.
IEEE Systems Journal,2014,8(4):1272-1282
|
被引
1
次
|
|
|
|
11.
Djeghali N. Sensorless fault tolerant control for induction motors.
International Journal of Control Automation and Systems,2013,11(3):563-576
|
被引
2
次
|
|
|
|
12.
Cusido J. Fault detection in induction machines using power spectral density in wavelet decomposition.
IEEE Transactions on Industrial Electronics,2008,55(2):633-643
|
被引
8
次
|
|
|
|
13.
祝洪宇. 负载连续变化时鼠笼电机早期转子断条故障诊断.
仪器仪表学报,2014,35(7):1646-1653
|
被引
7
次
|
|
|
|
14.
牛发亮. 基于电磁转矩小波变换的感应电机转子断条故障诊断.
中国电机工程学报,2005,25(24):122-127
|
被引
9
次
|
|
|
|
15.
Mallat S G. A theory for multiresolution signal decomposition :The wavelet representation.
IEEE Transactions on Pattern Analysis and Machine Intelligence,1989,11(7):674-693
|
被引
1779
次
|
|
|
|
16.
Zhang J K. Efficient design of orthonormal wavelet bases for signal representation.
IEEE Transactions on Signal Processing,2004,52(7):1983-1996
|
被引
3
次
|
|
|
|
|