海底观测网光电复合缆开路故障识别及区间定位方法
Open-circuit Fault Identification and Interval Locating Method of Optoelectric Cable of Seafloor Observatory Network
查看参考文献20篇
文摘
|
针对海底观测网络海底光电复合缆出现开路故障的问题,提出了采用平均测量残差值的方法识别开路故障。根据实时的网络拓扑结构与电流方向,建立有向图的邻接矩阵,将网络结构分成三种不同的区域。计算故障时刻前后的接驳盒电压变化差,利用差值进行开路故障的区域定位,针对耦合区域,提出了假设检验的方法进行开路故障海缆的区间定位。建立了海底观测网供电网络模型,进行了开路故障仿真分析,结果验证了该开路故障识别和定位方法的实用性和有效性。 |
其他语种文摘
|
For the problem of open-circuit fault with the optoelectric cable in the seafloor observatory network, a method of its identification by measuring the mean residual value is proposed. According to real-time network topology and current direction, an adjacency matrix of directed graph is built, to divide the network structure into three different areas. The voltage difference of the junction box across the moment the fault occurs is calculated and used for open-circuit fault section location. A hypothesis-testing method for the coupled regions is proposed to locate the section of the open-circuit fault. A model for the seafloor observatory network is developed and the open-circuit fault is analyzed by simulation. The results show that the method proposed is practical and efficient. |
来源
|
电力系统自动化
,2015,39(10):151-156 【核心库】
|
DOI
|
10.7500/aeps20140305006
|
关键词
|
海底观测网
;
光电复合缆
;
状态估计
;
开路故障
;
邻接矩阵
|
地址
|
中国科学院沈阳自动化研究所, 机器人学国家重点实验室, 辽宁, 沈阳, 110016
|
语种
|
中文 |
文献类型
|
研究性论文 |
ISSN
|
1000-1026 |
学科
|
自动化技术、计算机技术 |
文献收藏号
|
CSCD:5426343
|
参考文献 共
20
共1页
|
1.
朱心科. 海洋探测技术与装备发展探讨.
机器人,2013,35(3):376-384
|
被引
19
次
|
|
|
|
2.
汪品先. 从海底观察地球--地球系统的第三个观测平台.
自然杂志,2007,29(3):125-130
|
被引
38
次
|
|
|
|
3.
王克林. 加拿大海王星:科学、运行、管理.
地球科学进展,2013,28(5):521-528
|
被引
3
次
|
|
|
|
4.
Howe B M. Power system considerations for undersea observatories.
IEEE Trans on Oceanic Engineering,2002,27(2):267-274
|
被引
17
次
|
|
|
|
5.
Kirkham H. The design of the NEPTUNE power system.
Proceedings of the MTS/IEEE Oceans 2001 Conference,2001:1374-1380
|
被引
1
次
|
|
|
|
6.
Harris D W. Powering cabled ocean-bottom observatories.
IEEE Trans on Oceanic Engineering,2002,27(2):201-211
|
被引
12
次
|
|
|
|
7.
Kirkham H. The NEPTUNE power system: design from fundamentals.
The 3rd International Workshop on Scientific Use of Submarine Cables and Related Technologies,2003:301-306
|
被引
1
次
|
|
|
|
8.
Kojima J. Power systems for ocean regional cabled observatories.
Proceedings of the MTTS/IEEE TECHNO-OCEAN'04 Conference,2004:2176-2181
|
被引
1
次
|
|
|
|
9.
Lu Shuai. NEPTUNE power system:detection and location of switch malfunctions and high impedance faults.
2006 IEEE International Symposium on Industrial Electronics,2006:1960-1965
|
被引
3
次
|
|
|
|
10.
Chan T. Fault location for the NEPTUNE power system.
IEEE Trans on Power Systems,2007,22(2):522-531
|
被引
7
次
|
|
|
|
11.
El-Sharkawi M A. North east pacific time-integrated undersea networked experiments (NEPTUNE): cable switching and protection.
IEEE Trans on Oceanic Engineering,2005,30(1):232-240
|
被引
7
次
|
|
|
|
12.
Liu C C. State estimation for the NEPTUNE power system.
2003 IEEE PES Transmission and Distribution Conference and Exposition,2003:748-754
|
被引
2
次
|
|
|
|
13.
殷剑宏.
图论及其算法,2003
|
被引
70
次
|
|
|
|
14.
张宏. 基于邻接矩阵的配电网耦合点区域的分离.
继电器,2004,32(8):11-14
|
被引
1
次
|
|
|
|
15.
王阳. 基于图论的配电网故障行波定位新算法.
电力系统自动化,2012,36(18):143-147
|
被引
15
次
|
|
|
|
16.
刘柏私. 复杂中压配电网的可靠性评估分块算法.
中国电机工程学报,2005,25(4):40-45
|
被引
53
次
|
|
|
|
17.
Kothari D P.
Power system engineering,2009:894-900
|
被引
1
次
|
|
|
|
18.
熊信银.
电力系统工程基础,2002
|
被引
2
次
|
|
|
|
19.
Iyer H. Voltage profile improvement with distributed generation.
Proceedings of IEEE PES General Meeting,2005:2977-2984
|
被引
1
次
|
|
|
|
20.
Duan Jiandong. Study on power flow calculation and voltage profile in distribution system with distributed generation.
Proceedings of IEEE APPEEC,2009:1-4
|
被引
1
次
|
|
|
|
|