中红外吸收光谱测量激波风洞自由流中NO浓度和温度
Nitric oxide concentration and temperature measurement for shock tunnekl free stream using mid-infrared absorption spectroscopy
查看参考文献13篇
文摘
|
JF-10氢氧爆轰驱动激波风洞内的高焓自由来流气体中含有因电离和离解等非平衡过程产生的微量组分。利用可调谐二极管激光吸收光谱技术(TDLAS),对自由流中 NO 微量组分的浓度和温度进行测量,有助于定量理解气体电离和离解这一非平衡过程。本实验中,JF-10氢氧爆轰驱动激波风洞实验段内压力为百帕量级,在谱线加宽中多普勒加宽占据主导,多普勒半高宽可由分子平均热运动速度获得,其半高宽与温度的平方根成正比,因此选取一条吸收谱线并准确测定其多普勒半高宽即可得到温度和浓度。本实验中采用中红外量子级联激光器(Quantum Cascade Laser),选取1909.7cm~(-1)附近6条吸收线作为吸收线,在2kHz 的扫描频率下,采用直接吸收-波长扫描法进行 NO 温度和浓度测量。实验测得自由流中 NO 平均分压约为0.33Pa,自由流平均温度约为600K。 |
其他语种文摘
|
In this paper, JF-10 shock tunnel is driven by H_2/O_2 detonation and the free-stream contains some trace components which are generated by non-equilibrium processes such as ionization and dissociation. Tunable diode absorption spectroscopy (TDLAS) is used for temperature and concentration measurement of nitric oxide in the free-stream and this quantitative measurement is helpful to understand the non-equilibrium processes. In the experiments, the test section's static pressure of JF-10 shock tunnel is just several hPa. Thus, Doppler broadening dominates, which is caused by random thermal motion of the absorber species. The half width of Doppler broadening is temperature dependent and this functional relation provides a method for gas temperature and species concentration measurement. A mid-infrared quantum cascade laser of 5.2μm central wavelength is used and gas temperature and nitric oxide concentration are measured using a single line of 1909.7cm~(-1) wavelength by direct absorption-wavelength scanning method under 2kHz scanning frequency. The measured partial pressure of nitric oxide is about 0.33Pa which represents its concentration and the temperature is about 600K in the free-stream. |
来源
|
实验流体力学
,2015,29(2):79-83 【核心库】
|
DOI
|
10.11729/syltlx20140044
|
关键词
|
可调谐二极管激光吸收光谱
;
浓度
;
温度
;
测量
;
激波风洞
|
地址
|
中国科学院力学研究所, 高温气体动力学国家重点实验室, 北京, 100190
|
语种
|
中文 |
文献类型
|
研究性论文 |
ISSN
|
1672-9897 |
学科
|
航空 |
文献收藏号
|
CSCD:5415111
|
参考文献 共
13
共1页
|
1.
林贞彬. JF-10氢氧爆轰驱动激波风洞自由流的测量和诊断.
流体力学实验与测量,2000,14(3):12-17
|
被引
9
次
|
|
|
|
2.
Schulz C. Ultraviolet absorption spectra of shock-heated carbon dioxide and water between 900 and 3050K.
Chemical Physics Letters,2002,355(1):82-88
|
被引
1
次
|
|
|
|
3.
Arroyo M P. Dual diode-laser fiber-optic diagnostic for water-vapor measurements.
Optics Letters,1994,19(14):1091-1093
|
被引
3
次
|
|
|
|
4.
Farooq A. CO_2 concentrationand temperature sensor for combustion gases using diode-laser absorption near 2.7μm.
Applied Physics B,2008,90(3/4):619-628
|
被引
10
次
|
|
|
|
5.
Hanson R K. Shock tube spectroscopy: advanced instrumentation with a tunable diode laser.
Applied Optics,1977,16(6):1479-1481
|
被引
3
次
|
|
|
|
6.
Li H. Near-infrared diode laser absorption sensor for rapid measurements of temperature and water vapor in a shock tube.
Applied Physics B,2007,89(2/3):407-416
|
被引
18
次
|
|
|
|
7.
Mihalcea R M. Diode laser sensor for measurements of CO, CO_2, and CH_4 in combustion flows.
Applied Optics,1997,36(33):8745-8752
|
被引
15
次
|
|
|
|
8.
Sanders S T. Diode-laser sensor for monitoring multiple combustion parameters in pulse detonation engines.
Proceedings of the Combustion Institute,2000,28(1):587-594
|
被引
7
次
|
|
|
|
9.
余西龙. 利用可调谐二极管激光吸收光谱诊断超声速流动.
第二届高超声速科技学术会议,2009
|
被引
1
次
|
|
|
|
10.
李飞.
近红外吸收光谱诊断技术在超燃研究中的应用,2009
|
被引
1
次
|
|
|
|
11.
Hanson R K. Temperature measurement technique for high-temperature gases using a tunable diode laser.
Applied Optics,1978,17(16):2477-2480
|
被引
10
次
|
|
|
|
12.
Hanson R K. Tunable diode laser measurements in combustion gases.
27th Annual Techincal Symposium,1983:75-83
|
被引
1
次
|
|
|
|
13.
Rothman L S. The HITRAN 2008 molecular spectroscopic database.
Journal of Quantitative Spectroscopy and Radiative Transfer,2009,110(9):533-572
|
被引
126
次
|
|
|
|
|