非接触式电极在心电信号检测中的应用和研究进展
Application and Research Process of Non-contact Electrodes in ECG Detecting
查看参考文献28篇
文摘
|
非接触式心电电极不需要直接接触皮肤即可采集到心电信号,在使用中具有便捷、舒适、对皮肤状态完全不敏感等优点。本文对心电信号检测中常用的三类电极进行了概述和对比,对非接触式电极的工作原理、发展和现状进行了综述,最后对非接触式电极在载人航天领域的应用进行了展望。 |
其他语种文摘
|
Non-contact electrodes could detect ECG without skin contact which offers numerous advantages since non-contact electrodes are convenient,comfort and completely insensitive to skin conditions.In this paper, three types of ECG electrodes were compared and the basic principles and latest developments of non-contact electrodes were summarized.In the end,the application prospects of non-contact electrodes in manned spaceflight were discussed. |
来源
|
航天医学与医学工程
,2014,27(2):152-156 【扩展库】
|
关键词
|
载人航天
;
心电信号
;
心电检测
;
非接触式电极
|
地址
|
1.
中国航天员科研训练中心, 北京, 100094
2.
中国科学院空间科学与应用研究中心, 北京, 100190
|
语种
|
中文 |
文献类型
|
综述型 |
ISSN
|
1002-0837 |
学科
|
基础医学 |
基金
|
中国航天员科研训练中心飞天基金支持项目
|
文献收藏号
|
CSCD:5142107
|
参考文献 共
28
共2页
|
1.
王桂莲. 心电图电极.
数理医药学杂志,2007,20(4):541-542
|
被引
2
次
|
|
|
|
2.
黄志伟. 心电信号的检测技术与临床应用.
中国测试技术,2005,31(2):24-35
|
被引
2
次
|
|
|
|
3.
张汝果.
航天生物医学工程基础,1991:475
|
被引
1
次
|
|
|
|
4.
Chi Y M. Wireless non-contact cardiac and neural monitoring.
Wireless Health,2010:15-23
|
被引
2
次
|
|
|
|
5.
Neil Gandhi. Properties of Dry and Non-contact Electrodes for Wearable Physiological Sensors.
International Conference on Body Sensor Networks,2011:107-112
|
被引
1
次
|
|
|
|
6.
Chi Y M. Dry-Contact and noncontact biopotential electrodes: methodological review.
IEEE Reviews in Biomedical Engineering,2010,3:106-118
|
被引
18
次
|
|
|
|
7.
朱大缓.
非接触式心电监测系统的研究,2008
|
被引
1
次
|
|
|
|
8.
Richardson P C. Capacitive electrocardiographic and bioelectric electrodes.
IEEE transactions on Biomedical Engineering,1969,16(1):99
|
被引
7
次
|
|
|
|
9.
NASA Spinoff Database Record.
Heart Rate Monitors,2013
|
被引
1
次
|
|
|
|
10.
Matthews R. The invisible electrode- zero prep time, ultra low capacitive sensing.
The 11th International Conference on Human-Computer Interaction,2007:22-27
|
被引
1
次
|
|
|
|
11.
Lee J M. Evaluation of a capacitivelycoupled non-contact(through clothing) electrode or ECG monitoring and life signs detection for the objective force warfighter.
RTO HFM Symposium on Combat Casualty Care in Ground Based Tactical Situations: Trauma Technology and Emergency Medical Procedures,2004:1-10
|
被引
1
次
|
|
|
|
12.
Smith W J. Non-contact biopotential measurement from the human body using a low-impedance charge amplifier.
Bioengineering Conference,2004:31-32
|
被引
1
次
|
|
|
|
13.
Oum J H. Non-contact heartbeat sensor using LC oscillator circuit.
30th Annual International IEEE EMBS Conference,2008:4455-4458
|
被引
1
次
|
|
|
|
14.
Oum J H. Non-contact heartbeat and respiration detector using capacitive sensor with Colpitts oscillator.
Electronics Letters,2008,44(2):87-89
|
被引
1
次
|
|
|
|
15.
Chi Y M. Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation.
Engineering in Medicine and Biology Society,2009:4218-4221
|
被引
2
次
|
|
|
|
16.
Chi Y M. Non-contact low power eeg / ecg electrode for high density wearable biopotential sensor networks.
Wearable and Implantable Body Sensor Networks Sixth International Workshop,2009:246-250
|
被引
1
次
|
|
|
|
17.
Chi Y M. Wireless non-contact EEG/ECG electrodes for body sensor networks.
Body Sensor Networks 2010 International Conference,2010:297-301
|
被引
1
次
|
|
|
|
18.
Chi Y M. Wireless non-contact cardiac and neural monitoring.
WH '10 Wireless Health,2010:15-23
|
被引
1
次
|
|
|
|
19.
Zhu D H. A non-contact ECG measurement system for pervasive heart rate detection.
Proceedings of the 5th International Conference on Information Technology and Application in Biomedicine,2008:518-519
|
被引
1
次
|
|
|
|
20.
Akinori U. Unconstrained monitoring of ECG and respiratory variation in infants with underwear during sleep using a bed-sheet electrode unit.
30th Annual International IEEE EMBS Conference Vancouver,2008:2329-2332
|
被引
1
次
|
|
|
|
|