文摘
|
针对重离子治癌中的束流监测需要,用T型反馈电阻网络组成的电流-电压转换(IVC)电路将大面积二维位置灵敏平行板雪崩探测器(PPAC)输出的多路10 pA~100 nA的微弱电流转换成-2 V~-20 mV的电压信号,配合数据获取处理系统实现了近代物理研究所重离子治癌中的束流均匀性测量。实验表明该电路具有速度快、精度高等优点,该电路也可用于法拉第筒及多丝正比室的束流读出。 |
其他语种文摘
|
It introduces a circuit design of beam homogeneity measurement for heavy ion beam in the monitoring needs,which convert multichannel weak current from 10 pA to 100 nA of the output of parallel plate avalanche counter(PPAC)for large area with sensitive two-dimensional position to voltage signal from-2 V to-20 mV by current-voltage-convertor(IVC)circuit which composed of T-feedback resistor networks,combined with data acquisition and processing system realized the beam homogeneity measurement in heavy ion tumor therapy of the Institute of Modern Physics.Experiments have shown that the circuit with speed and high precision,This circuit can be used for read-out of the beam for the Multiwire Proportional Chamber,Faraday Cup and other weak current sources. |
来源
|
核电子学与探测技术
,2011,31(6):646-651 【核心库】
|
关键词
|
束流均匀性
;
电流电压转换
;
T型反馈电阻网络
;
重离子治癌
|
地址
|
中国科学院近代物理研究所, 兰州, 730000
|
语种
|
中文 |
文献类型
|
研究性论文 |
ISSN
|
0258-0934 |
学科
|
原子能技术 |
基金
|
中国科学院知识创新工程重要方向项目
|
文献收藏号
|
CSCD:4270875
|
|
1.
唐彬. 重离子浅层治癌中的束流监测装置.
核电子学与探测技术,2008,28(4):699-701
|
被引
4
次
|
|
|
|
2.
苏弘. 一种束流强度监测电路设计.
核电子学与探测技术,2009,29(5):1051-1054
|
被引
3
次
|
|
|
|
3.
王立新. pA级微电流测量技术研究.
仪表技术,1999(4):34-36
|
被引
6
次
|
|
|
|
4.
陈文芗. 采用积分型电路的微电流测量.
分析仪器,1998(3):22-24
|
被引
2
次
|
|
|
|
5.
刘鹏民. T型反馈电阻网络在微弱信号放大电路中的应用.
电测与仪表,1999,36(12):31-32
|
被引
7
次
|
|
|
|
6.
周红. 电分析仪器中的微电流测量.
分析仪器,2000(2):20-23
|
被引
5
次
|
|
|
|
7.
张建慧. 高频布线工艺和PCB板选材.
无线电工程,2001,31(2):32-36
|
被引
2
次
|
|
|