全极化微波辐射计模拟复相关器研究
Study on Analog Complex Correlator for Fully Polarized Radiometer

查看参考文献8篇

文摘 全极化微波辐射计是一种新型的微波遥感器,制约其发展的关键部件是相关器.提出了一种应用在此新系统中的模拟复相关器,其具有灵敏度高,体积小,功耗低等优点.对模拟复相关器进行误差分析,给出减少复相关幅度误差和相位误差的方案.按此方案对模拟复相关器进行了设计,研制.得到了模拟复相关器整体测量结果及全极化微波辐射计噪声测量结果.结果表明采用此模拟复相关器的全极化微波辐射计具有较好的极化测量性能
其他语种文摘 Fully polarized radiometer is a new technique in radiation measurements. The analog complex correlator is the key component. The advantages of the correlator are lower power consumption(compared to a digital correlator), small chip area and high sensitivity. The error analysis of the analog complex correlator is carried out and some suggestions are given to reduce the amplitude error and phase error. According to results of error analysis, its structure, application, manufacture and performance are also discussed and their results are presented. At last, the analog complex correlator measurement results and noise measurements results of the fully polarized radiometer have been given out. The results show that fully polarized radiometer with an analog correlator has a good performance in polarization measurement
来源 宇航学报 ,2011,32(3):604-612 【核心库】
DOI 10.3873/j.issn.1000-1328.2011.03.023
关键词 全极化微波辐射计 ; 复相关器 ; 模拟乘法器
地址

中国科学院空间科学与应用研究中心, 北京, 100190

语种 中文
文献类型 研究性论文
ISSN 1000-1328
学科 测绘学
文献收藏号 CSCD:4165258

参考文献 共 8 共1页

1.  Yueh S H. Polarimetric measurements of sea surface brightness temperatures using an aircraft K-band radiometer. IEEE Transactions on Geosciences and Remote Sensing,1995,33(1):85-92 被引 11    
2.  Yueh S H. Polarimetric micro wave brightness signatures of ocean wind directions. IEEE Trails. Geosci.and Remote Sensing,1999,37(7):949-959 被引 8    
3.  Lahtinen J. A low-cost polarimetric radiometer for real time stokes parameter measurement. Proc. IGARSS,1997:1597-1599 被引 1    
4.  Ulaby F T. Microwave remote sensing active and passive. Volume 1,1981:455-456 被引 1    
5.  董晓龙. 信道互耦和不平衡度对综合孔径微波辐射计复相关干涉测量的影响分析及其校准. 电子学报,2001,29(7):947-949 被引 8    
6.  庄小利. 综合孔径微波辐射计的模拟乘法器及其外围电路的实现[硕士论文],2006:35-36 被引 1    
7.  刘璟怡. 全极化微波辐射计定标和风场反演若干问题研究[博士论文],2007:98-99 被引 1    
8.  Koistinen O. Comparison of analog continuum correlators for remote sensing and radio astronomy. IEEE Transactions on Instrumentation and Measurement,2002,51(2):227-234 被引 1    
引证文献 1

1 杨晓城 FPIR双极化亮温的反演 宇航学报,2013,34(10):1387-1393
被引 0 次

显示所有1篇文献

论文科学数据集
PlumX Metrics
相关文献

 作者相关
 关键词相关
 参考文献相关

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心
地址:北京中关村北四环西路33号 邮政编码:100190 联系电话:(010)82627496 E-mail:cscd@mail.las.ac.cn 京ICP备05002861号-4 | 京公网安备11010802043238号