帮助 关于我们

返回检索结果

乳腺肿块微血管密度与血氧近红外光参数的实验研究
Experimental Study on Near-infrared Parameters of Blood Oxygen and Microvessei Density of Manmmry Gland Phyma

查看参考文献5篇

文摘 目的从组织微血管分布密度初探乳腺肿块血氧近红外光参数的可靠性。方法用近红外光TBO—I型双波长乳腺肿瘤检测仪,对检测的181例乳腺肿块进行近红外光血氧参数分类和病理切片检查明确肿块性质,并对其中20例恶性肿块和20例良性肿块进行免疫组织化学SP法检测乳腺肿块微血管密度,运用医学统计学方法分析近红外光血氧参数与微血管密度的相关性。结果(1)28例高血乳腺肿块微血管密度值和血含量值分别为24.56±8.110和1.891±0.850,12例低血乳腺肿块微血管密度值和血含量值分别为17.98±8.729和0.698±0.283,两者比较存在显著性差异(P〈0.05);(2)40例乳腺肿块的微血管密度值与近红外光血含量值直线相关系数为r=0.4208(P〈0.05)。结论乳腺良、恶性肿块局部微血管密度与其血含量近红外检测参数存在相关性,说明了近红外光血含量检测参数作为诊断乳腺癌标准的可靠性。
其他语种文摘 Objective To detect the reliability of near-infrared parameters of blood oxygen of mammary gland phyma from the microvessel density of tumor. Methods 181 cases of mammary gland pryma who had accept the examination of the near-infrared TBO-I dual-wave length mammary gland phyma dedecfor were classified by near-infrared parameters of blood oxygen, and were performed the pathologic exmination to ascertain whether tumor is benign or malignant. Out of these cases, intratumor microvessel density of 20 cases of malignant phyma and 20 cases of benign phyma were confirm by s-p immunohistochemical methods, then the relation among near-infrared parameters and microvessel density were analyzed by medical statistics. Results (1)The microvessel density and blood concentration of 28 cases of the"high blood" tumor was 24. 56 ± 8. 110,1. 891 ± 0. 850 respectively. The microvessel density and blood concentration of 12 cases of the "low blood" was 17. 98 ± 8. 729, 0. 698 ± 0. 283 respectively. There is significant difference between the "high blood" tumor and "low blood" tumor. (P〈0. 05). (2) The intratumor microvessel density and blood concertration is linearly correlated respectively, the linear correlation coefficient r = 0. 4208 (P〈0. 05)in 40 cases of mammary gland phyma. Conclusion The intratumor microvessel density of benign or malignant mammary gland phyma and blood concentration is linearly correlated. Blood concentration (one of near-infrared parameters) is reliable to be used as dignosis criterion of malignant mammary gland phyma.
来源 肿瘤防治研究 ,2007,34(1):51-53 【扩展库】
关键词 乳腺肿块 ; 微血管密度 ; 血氧近红外光参数
地址

华中科技大学同济医学院附属荆州医院普外科, 湖北, 荆州, 434020

语种 中文
文献类型 研究性论文
ISSN 1000-8578
学科 肿瘤学
文献收藏号 CSCD:2755254

参考文献 共 5 共1页

1.  谢则平. 近红外光无创伤诊断乳腺癌的临床研究. 癌症,2000,19(2):185 被引 4    
2.  纪小龙. 诊断免疫组织化学,1997:19-21 被引 2    
3.  Li X. Tumor localization using fluorescence of Indocyanine green(ICG)in rat models. SPIE 2389,1995:789-797 被引 1    
4.  Nioka S. Optical imaging of breast tumor by means of continuous waves. Adv Exp Med Biol,1997,411:227-232 被引 1    
5.  Hawrysz D. Developments Toward Diagnostic Breast Cancer Imaging Using Near-Infrared Optical Measurements and Fluorescent Contrast Agents. Neoplasia,2000,2(5):388-417 被引 2    
引证文献 8

1 侯新燕 超声光散射乳腺成像技术在乳腺疾病诊断中的应用 中国超声医学杂志,2008,24(4):315-318
被引 2

2 陈馨 乳腺三算子与血氧功能成像诊断系统对乳腺肿瘤的诊断研究 肿瘤防治研究,2008,35(5):365-366
被引 2

显示所有8篇文献

论文科学数据集
PlumX Metrics
相关文献

 作者相关
 关键词相关
 参考文献相关

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心
地址:北京中关村北四环西路33号 邮政编码:100190 联系电话:(010)82627496 E-mail:cscd@mail.las.ac.cn 京ICP备05002861号-4 | 京公网安备11010802043238号