炉内配风方式对锅炉经济性的影响
INFLUENCE OF AIR DISTRIBUTIOM IN THE FURNACE ON ECONOMICAL OPERATION OF THE BOILER

查看参考文献4篇

吴东垠 1   魏小林 2   盛宏至 2   徐永香 2   李华民 3  
文摘 本文以炉内配风方式对锅炉经济性的影响为研究对象.当机组负荷为300 MW时,省煤器出口的最佳氧量为3.4%左右;当机组负荷为225 MW时,省煤器出口的最佳氧量为4.6%左右;就二次风的组合方式而言,在高温区保持适宜的氧气浓度,可以提高反应速度,保证煤粉颗粒的燃尽,提高锅炉的经济性,而燃尽风的风门开度选择主要考虑降低锅炉的气体排放物(主要是NOx),对炉内燃烧效果影响不大.
其他语种文摘 The influence of air distribution in the furnace on economical operation of the boiler is investigated. For 300 MWe electrical load, the optimal O2 concentration is 3.4% at outlet of economizer, and for 225 MWe electrical load, the optimal O2 concentration is 4.6%. From the view of assembled way of secondary airs, the optimal O2 concentration maintained in the high temperature zone can enhance the char reactive rate and improve the burnout of coal particle as well as the economical operation of the boiler. The selection of opening degree of the burnout air value is concerned to decrease the pollutant emission (mainly for NOX), which only has less influence on the combustion efficiency in the furnace.
来源 工程热物理学报 ,2005,26(1):163-166 【核心库】
关键词 锅炉 ; 总风量 ; 二次风 ; 经济性
地址

1. 天津大学, 内燃机燃烧学国家重点实验室, 天津, 300072  

2. 中国科学院力学研究所, 北京, 100080  

3. 华能天津杨柳青发电厂, 天津, 300080

语种 中文
文献类型 研究性论文
ISSN 0253-231X
学科 能源与动力工程
基金 国家自然科学基金资助项目
文献收藏号 CSCD:1867527

参考文献 共 4 共1页

1.  . 中华人民共和国国家标准. 中华人民共和国国家标准.电站锅炉性能试验规程.GB10184-88,1988 被引 1    
2.  吴东垠. 410 t/h燃煤锅炉的优化燃烧试验. 锅炉制造,2002,24(4):6-9 被引 2    
3.  吴东垠. 切向燃烧锅炉水平烟道烟温偏差的起因及改进措施. 电站系统工程,1997,13(4):34-36 被引 2    
4.  许传凯. 大型燃煤电厂锅炉运行现状分析. 中国电力,2003,36(1):1-5 被引 4    
引证文献 3

1 宁新宇 低NO_x切向燃烧系统的改造及性能优化试验 动力工程学报,2010,30(7):502-507
被引 2

2 梁绍华 双炉膛四角切圆煤粉锅炉分层掺烧数值模拟及性能试验研究 中国电机工程学报,2011,31(26):9-15
被引 3

显示所有3篇文献

论文科学数据集
PlumX Metrics
相关文献

 作者相关
 关键词相关
 参考文献相关

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心