文摘
|
利用电化学方法,结合XRD、EDX、SEM和EPMA等表面分析技术,研究了经超声喷丸表面纳米化的Fe-20Cr合金在0.05mol/L H2SO4+0.5mol/L NaCl溶液中的腐蚀性能。结果表明,纳米化后合金的耐蚀性能降低。相对于粗晶合金,纳米材料晶粒的细化、钝化金属中Cr元素分析的均匀性降低以及超声喷丸技术在制备纳米晶过程中所带来的残余应力是纳米材料耐蚀性能降低的原因。 |
其他语种文摘
|
Electrochemical methods and XRD,EDX,SEM, EPMA technique were used to investigate the corro-sion performance of nanocrystallized Fe - 20Cr surface which was fabricated by using an ultrasonic shot .peening (USSP)technique, and the corrosion solution was 0.05 mol/L F_2SO_4 + 0.5 mol/L NaCl.The results show that the capability of corrosion resistance of the SNC Fe - 20Cr alloy was lower than that of the cast alloy. Contrast to the cast alloy, the reduction of the grain size, the less uniform passive element of Cr, and the remnant strain caused by USSP technique are thought to be the main reasons which result in the poorer corrosion resistance of nanocrystal alloy. |
来源
|
中国腐蚀与防护学报
,2002,22(6):326-329,334 【核心库】
|
关键词
|
超声喷丸
;
表面纳米化
;
Fe-20Cr
;
钝化
;
残余应力
|
地址
|
1.
中国科学院金属研究所, 金属腐蚀与防护国家重点实验室, 沈阳, 110016
2.
中国科学院金属研究所, 快速凝固非平衡国家重点实验室, 沈阳, 110016
|
语种
|
中文 |
文献类型
|
研究性论文 |
ISSN
|
1005-4537 |
学科
|
金属学与金属工艺 |
基金
|
国家自然科学基金
|
文献收藏号
|
CSCD:1121710
|