文摘 采用近红外光谱法快速测定了三基发射药干燥过程的总挥(醇酮溶剂)含量;通过对比三基发射药药粒样品及总挥的光谱图特点,确定了总挥最佳建模光谱范围;对三基发射药样品的光谱图进行预处理,对比了不同光谱预处理方法的效果,最终确定了最佳光谱预处理方法;采用偏最小二乘法建立了三基发射药样品总挥的校正模型,最终选择总挥建模的最佳主因子数为8,并对模型的预测能力进行了验证。结果表明,确定的最优建模光谱区间为5 700~6 100 cm~(-1),最佳光谱预处理方法为一阶导数+SNV的组合,总挥含量模型的校正决定系数(R2 C)为0.970 3,校正均方根误差(RMSEC)为0.149 7;预测决定系数(R2P)为0.962 8,预测均方根误差(RMSEP)为0.187 9;验证集标准偏差与预测标准偏差的比值(RPD)为6.7;将该模型应用到三基发射药干燥过程总挥含量的检测,预测平均偏差为0.025%,建立的总挥模型具有较好的预测性和重复性,在60 s内可实现三基发射药干燥过程总挥含量的准确检测。
其他语种文摘 The total volatile(alcohol and ketone)content of triple-based gun propellant during drying process was quickly determined by near-infrared spectroscopy.By comparing the spectral characteristics of triple-based gun propellant sample and the total volatile,the optimal modeling spectrum of the total volatile was determined.The optimum spectral pretreatment method was finally confirmed,depending on the effect of spectra pretreating methods of triple-based gun propellant.The calibration model of triple-based gun propellant was established by partial least squares method(PLS),and the optimal principal factor of the total volatile model was chosen as 8,and the prediction ability of the model was demonstrated.The results show that the optimal spectral range is 5 700-6 100 cm~(-1),and the best spectral pretreating method is the combination of first order derivative and SNV.The determination coefficient of the calibration(R2 C)is 0.970 3,the root mean square error of calibration(RMSEC) is 0.149 7;the determination coefficient of prediction(R2P)is 0.962 8,and the root mean square error of prediction (RMSEP)is 0.187 9.The ratio of the standard deviation of the validation set to standard error of prediction(RPD)of the total volatile model is 6.7.The model is applied to the detection of the total volatile content in the drying process of triple-based gun propellant,the average deviation of the predicted value is 0.025%.This method exhibited good predictive performance and repeatability,which can realize the accurate detection of the total volatile content during the drying process of triple-based gun propellant in 60 s.
来源 火炸药学报 ,2020,43(4):419-423,427 【核心库】
DOI 10.14077/j.issn.1007-7812.201908008
关键词 分析化学 ; 三基发射药 ; 总挥含量 ; 近红外光谱 ; 快速检测 ; 组分模型
地址

1. 南京理工大学, 国家特种超细粉体工程技术研究中心, 江苏, 南京, 210094  

2. 辽宁庆阳特种化工有限公司, 辽宁, 辽阳, 111000

语种 中文
文献类型 研究性论文
ISSN 1007-7812
学科 化学;武器工业
基金 国防科研专项项目
文献收藏号 CSCD:6797230

参考文献 共 20 共1页

1.  Barton F E. Analysis of fiber content in flax stems by near-infrared spectroscopy. Journal of Agricultural and Food Chemistry,2002,50(26):7576-7580 CSCD被引 2    
2.  Huang Z. Feasibility study of near infrared spectroscopy with variable selection for nondestructive determination of quality parameters in shell-intact cottonseed. Industrial Crops and Products,2013,43:654-660 CSCD被引 10    
3.  Lopez A. A review of the application of near-infrared spectroscopy for the analysis of potatoes. Journal of Agricultural and Food Chemistry,2013,61(23):5413-5424 CSCD被引 5    
4.  Chen Q. Feasibility study on qualitative and quantitative analysis in tea by near infrared spectroscopy with multivariate calibration. Analytica Chimica Acta,2006,572(1):77-84 CSCD被引 18    
5.  Xie L. Combination and comparison of chemometrics methods for identification of transgenic tomatoes using visible and near-infrared diffuse transmittance technique. Journal of Food Engineering,2007,82(3):395-401 CSCD被引 5    
6.  Mamani-Linares L W. Identification of cattle,llama and horse meat by near infrared reflectance or transflectance spectroscopy. Meat Science,2012,90(2):378-385 CSCD被引 13    
7.  Woodcock T. Application of near and mid-infrared spectroscopy to determine cheese quality and authenticity. Food and Bioprocess Technology,2008,1(2):117-129 CSCD被引 2    
8.  何东健. 水果内部品质在线近红外分光检测装置及试验. 农业工程学报,2001,17(1):146-148 CSCD被引 29    
9.  刘荔荔. 近红外漫反射光谱法在羊蹄类生药分类中的应用. 中草药,2001,32(11):1024-1026 CSCD被引 11    
10.  Li W. Measurement of drug agglomerates in powder blending simulation samples by near infrared chemical imaging. International Journal of Pharmaceutics,2008,350(1):369-373 CSCD被引 2    
11.  Mark J. Online process control of a pharmaceutical intermediate in a fluidized-bed drier environment using near-infrared spectroscopy. Analytical Chemistry,2010,82(10):4209-4215 CSCD被引 5    
12.  Rantanen J. Use of inline near-infrared spectroscopy in combination with chemometrics for improved understanding of pharmaceutical processes. Analytical Chemistry,2005,77(2):556-563 CSCD被引 9    
13.  黄友之. 含能材料的近红外光谱检测. 材料科学与工程新进展,2002:1041-1043 CSCD被引 1    
14.  苏鹏飞. 近红外漫反射光谱法快速测定混合炸药组分含量. 火炸药学报,2008,31(5):62-65 CSCD被引 16    
15.  Zhou S. Rapid quantification of stabilizing agents in single-base propellants using near infrared spectroscopy. Infrared Physics & Technology,2016,77:1-7 CSCD被引 6    
16.  Xiaoboa Z. Variables selection methods in near-infrared spectroscopy. Analytica Chimica Acta,2010,667(1):14-32 CSCD被引 102    
17.  Leardi R. Sequential application of backward interval partial least squares and genetic of relevant spectral regions. Journal of Chemometrics,2004,18(11):486-497 CSCD被引 49    
18.  Jin Ye. Near infrared spectroscopy in combination with chemometrics as a process analytical technology tool for on-line quantitative monitoring of alcohol precipitation. Journal of Pharmaceutical and Biomedical Analysis,2013,77(5):32-39 CSCD被引 18    
19.  Zou Quan. A green analytical tool for in-process determination of propellant using the NIR system. ACS Sustainable Chemistry & Engineering,2013,1(12):1506-1510 CSCD被引 6    
20.  龚益飞. 近红外光谱法在线判断滴丸料液混合终点. 中国药学杂志,2007,42(7):509-511 CSCD被引 14    
引证文献 1

1 黄子淇 近红外技术在含能材料领域的应用研究进展 兵器装备工程学报,2022,43(7):58-66,77
CSCD被引 0 次

显示所有1篇文献

论文科学数据集
PlumX Metrics
相关文献

 作者相关
 关键词相关
 参考文献相关

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心
地址:北京中关村北四环西路33号 邮政编码:100190 联系电话:(010)82627496 E-mail:cscd@mail.las.ac.cn 京ICP备05002861号-4 | 京公网安备11010802043238号