A multicenter hospital-based diagnosis study of automated breast ultrasound system in detecting breast cancer among Chinese women

查看参考文献31篇

Zhang Xi 1   Lin Xi 2   Tan Yanjuan 3   Zhu Ying 4   Wang Hui 5   Feng Ruimei 6   Tang Guoxue 2   Zhou Xiang 7   Li Anhua 2   Qiao Youlin 1 *  
文摘 Objective: The automated breast ultrasound system (ABUS) is a potential method for breast cancer detection; however, its diagnostic performance remains unclear. We conducted a hospital-based multicenter diagnostic study to evaluate the clinical performance of the ABUS for breast cancer detection by comparing it to handheld ultrasound (HHUS) and mammography (MG). Methods: Eligible participants underwent HHUS and ABUS testing; women aged 40–69 years additionally underwent MG. Images were interpreted using the Breast Imaging Reporting and Data System (BI-RADS). Women in the BI-RADS categories 1–2 were considered negative. Women classified as BI-RADS 3 underwent magnetic resonance imaging to distinguish true- and false-negative results. Core aspiration or surgical biopsy was performed in women classified as BI-RADS 4–5, followed by a pathological diagnosis. Kappa values and agreement rates were calculated between ABUS, HHUS and MG. Results: A total of 1,973 women were included in the final analysis. Of these, 1,353 (68.6%) and 620 (31.4%) were classified as BI-RADS categories 1–3 and 4–5, respectively. In the older age group, the agreement rate and Kappa value between the ABUS and HHUS were 94.0% and 0.860 (P<0.001), respectively; they were 89.2% and 0.735 (P<0.001) between the ABUS and MG, respectively. Regarding consistency between imaging and pathology results, 78.6% of women classified as BI-RADS 4–5 based on the ABUS were diagnosed with precancerous lesions or cancer; which was 7.2% higher than that of women based on HHUS. For BI-RADS 1–2, the false-negative rates of the ABUS and HHUS were almost identical and were much lower than those of MG. Conclusions: We observed a good diagnostic reliability for the ABUS. Considering its performance for breast cancer detection in women with high-density breasts and its lower operator dependence, the ABUS is a promising option for breast cancer detection in China.
来源 Chinese Journal of Cancer Research ,2018,30(2):231-239 【核心库】
DOI 10.21147/j.issn.1000-9604.2018.02.06
关键词 Automated breast ultrasound system ; breast neoplasms ; China
地址

1. Department of Epidemiology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021  

2. Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in Southern China, Guangzhou, 510060  

3. Department of Ultrasound, the First People's Hospital of Hangzhou, Affiliated Hangzhou Hospital of Nanjing Medical University, Hangzhou, 310006  

4. Department of Breast Imaging, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin, 300060  

5. Department of Ultrasound, Xin Hua Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200092  

6. Department of Cancer Prevention Research, Sun Yat-Sen University Cancer Center, Guangzhou, 510060  

7. Department of Interventional Radiology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021

语种 英文
文献类型 研究性论文
ISSN 1000-9604
学科 临床医学;肿瘤学
基金 supported by GE Healthcare
文献收藏号 CSCD:6249902

参考文献 共 31 共2页

1.  ScienceChina 中国科学文献服务系统

您还没有权限

 


请您 返回ScienceChina—中国科学文献服务系统首页重新检索,如果您在使用ScienceChina—中国科学文献服务系统遇到问题。

销售咨询联系:

北京中科进出口有限责任公司

联系电话: (010) 84039345-635

电子邮件:chuw@bjzhongke.com.cn

联系地址:北京市东城区安定门外大街138号皇城国际大厦B座801 100011

服务咨询联系:

中国科学院文献情报中心

联系电话: (010) 82627496

传 真:(010) 82627496

电子邮件:cscd@mail.las.ac.cn

联系地址:北京市 海淀区 北四环西路33号 100190

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心
地址:北京中关村北四环西路33号 邮政编码:100190 联系电话:(010)82627496 E-mail:cscd@mail.las.ac.cn 京ICP备05002861号-4 | 京公网安备11010802043238号