基于工业计算机断层成像的装药底隙无损检测方法研究
Inspection of Base separation of Charge by Industrial CT Imaging
查看参考文献9篇
文摘
|
在弹药装药底隙检测中,运用密度对比法结合体积效应,将底隙测量转化为弹底密度变化的测量,建立弹底扫描断层中心部位计算机断层成像(CT)值变化与底隙值之间的数学模型,解决底隙测量理论与实际操作中的难题。预置底隙测量实验结果表明:该模型可完成对0.20~0.50mm底隙的测量,最大相对误差小于3.5%,可实现对装药底隙的定性判断与定量检测。 |
其他语种文摘
|
A volume effect of industrial computed tomography(CT) imaging and a contrast method for density inspection are used to build an algebraic model for base separation inspection, which improves the base separation inspection method in theoretical and practical ways. The size information is qualitatively and quantitatively analyzed with high precision by the fluctuation of inspected CT values. The experimental results of base separation inspection show that the density contrast model is suitable for the inspection of 0.20~0.50mm base separation, and the relative error is less than 3.5%. |
来源
|
兵工学报
,2015,36(1):157-162 【核心库】
|
DOI
|
10.3969/j.issn.1000-1093.2015.01.023
|
关键词
|
兵器科学与技术
;
工业计算机断层成像
;
密度对比
;
底隙
;
定量检测
|
地址
|
北京理工大学, 爆炸科学与技术国家重点实验室, 北京, 100081
|
语种
|
中文 |
文献类型
|
研究性论文 |
ISSN
|
1000-1093 |
学科
|
武器工业 |
文献收藏号
|
CSCD:5370748
|
参考文献 共
9
共1页
|
1.
Starkenberg J. Ignition of solid high explosive by the rapid compression of an adjacent gas layer.
Proceedings of 7th International Symposium on Detonation,1981:3-16
|
CSCD被引
1
次
|
|
|
|
2.
李文彬. 装药底隙对弹底应力及发射安全性影响研究.
弹道学报,2001,13(3):64-67
|
CSCD被引
8
次
|
|
|
|
3.
卢艳平. 基于工业CT成像的弹药小底隙测量方法研究.
兵工学报,2009,30(12):1714-1717
|
CSCD被引
2
次
|
|
|
|
4.
周培毅. 炸药装药在后座冲击条件下的点火模型研究.
火炸药学报,2000,1(1):1-5
|
CSCD被引
6
次
|
|
|
|
5.
United States Department of Defense.
MIL-P-63252A Projectile, 155mm, HE, M795 loading, assembling and packing; military specification,1995
|
CSCD被引
1
次
|
|
|
|
6.
卢国胜. 中大口径榴弹采用ICT检验注装药底隙方案研究.
弹箭与制导学报,2010,30(1):121-123
|
CSCD被引
1
次
|
|
|
|
7.
Wells K. Quantifying the partial volume effect in PET using Benford's law.
IEEE Transactions on Nuclear Science,2007,54(5):1616-1625
|
CSCD被引
1
次
|
|
|
|
8.
Dehmeshki J. Volumetric quantification of atherosclerotic plaque in CT considering partial volume effect.
IEEE Transactions on Medical Imaging,2007,26(3):273-282
|
CSCD被引
3
次
|
|
|
|
9.
Kropas C V. Effect of composition on density measurement by X-ray computed tomography.
Materials Evaluation,1991,49(4):487-489
|
CSCD被引
3
次
|
|
|
|
|