Evaluation of entropy for monitoring the depth of anesthesia compared with bispectral index: a multicenter clinical trial
查看参考文献21篇
文摘
|
Background As a new electroencephalogram (EEG) signal processing technique for monitoring the depth of anesthesia, entropy consists of two indices: reaction entropy (RE) and state entropy (SE). Our study compared entropy with classical bispectral index (BIS) in reduction of myoelectrical interference and noxious stimuli with EEG signals. Methods Two hundred and eighty patients (ASA I–II, 18–60 years old) undergoing scheduled surgeries from seven medical centers were enrolled. Anesthesia induction was managed with propofol via the target-controlled infusion (TCI) system. The results of BIS, RE, SE, mean arterial pressure (MAP) and heart rate (HR) were recorded before anesthesia induction, at the moment of unconsciousness, before and 2 minutes after administration of muscle relaxant, and before and one and three minutes after the tracheal intubation. Results The values of half maximum effective concentrations (EC50), 5% effective concentrations (EC05) and 95% effective concentrations (EC95) of propofol effect-site concentration at the onset of unconsciousness were 1.2 (1.1–1.3 μg/ml), 2.5 (2.4–2.5 μg/ml) and 3.7 (3.7–3.8 μg/ml), while those of the predicted plasma propofol concentration were 2.8 (2.7–2.9 μg/ml), 3.9 (3.8–3.9 μg/ml) and 4.9 (4.8–5.0 μg/ml), respectively. The values of BIS, SE and RE were 62, 59 and 63 when 50% of patients lost consciousness, and 79, 80, 85 and 42, 37, 44, respectively, when 5% and 95% of patients were unconscious. The values of BIS, RE and SE dropped two minutes after the injection of muscle relaxant, but there were no significant differences between RE and SE. MAP and HR increased visibly, which indicated a reaction to tracheal intubation; the values of BIS, RE and SE, however, did not display any significant changes. Conclusions This large-sample multicentric study confirmed the values of RE and SE as approximating BIS value, at the onset of unconsciousness during propofol TCI anesthesia. After elimination of myoelectrical activation, all values of RE, SE and BIS decreased significantly and the three indices were less sensitive to noxious stimuli than cardiovascular responses. |
来源
|
Chinese Medical Journal
,2012,125(8):1389-1392 【核心库】
|
DOI
|
10.3760/cma.j.issn.0366-6999.2012.08.005
|
关键词
|
propofol
;
target-controlled infusion
;
unconsciousness
;
bispectral index
;
entropy
;
dose-response relationship
|
地址
|
1.
Department of Anesthesiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100020
2.
Department of Anesthesiology, Chinese Academy of Medical Sciences and Peking Union Medical College Hospital, Beijing, 100730
3.
Department of Anesthesiology, Xuanwu Hospital, Capital Medical University, Beijing, 100053
4.
Department of Anesthesiology, First Affiliated Hospital of China Medical University, Liaoning, Shenyang, 110001
5.
Department of Anesthesiology, Tangdu Hospital, Fourth Military Medical University, Shaanxi, Xi’an, 710038
6.
Department of Anesthesiology, Shanghai Cancer Hospital, Fudan University, Shanghai, 200032
7.
Department of Anesthesiology, Guangzhou Cancer Institute and Hospital, Guangzhou Medical University, Guangdong, Guangzhou, 510080
|
语种
|
英文 |
文献类型
|
研究性论文 |
ISSN
|
0366-6999 |
学科
|
外科学 |
文献收藏号
|
CSCD:4498353
|
参考文献 共
21
共2页
|
1.
Nieuwenhuijs D. Bispectral index values and spectral edge frequency at different stages of physiologic sleep.
Anesth Analg,2002,94:125-129
|
CSCD被引
4
次
|
|
|
|
2.
Paloheima M. Quantitative surface electromyography (qEMG): applications in anesthesiology and critical care.
Acta Anaesthesiol Scand Suppl,1990,93:1-83
|
CSCD被引
1
次
|
|
|
|
3.
Maksimow A. Increase in high frequency EEG activity explains the poor performance of EEG spectral entropy monitor during S-ketamine anesthesia.
Clin Neurophysiol,2006,117:1660-1668
|
CSCD被引
2
次
|
|
|
|
4.
Smith W D. Measuring the performance of anesthetic depth indicators.
Anesthesiology,1996,84:38-51
|
CSCD被引
33
次
|
|
|
|
5.
Bruhn J. Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia.
Anesthesiology,2000,92:715-726
|
CSCD被引
14
次
|
|
|
|
6.
Viertio-Oja H. Description of the entropy algorithm as applied in the detex-omeda S/5 entropy module.
Acta Anaesthesiol Scand,2004,48:154-161
|
CSCD被引
24
次
|
|
|
|
7.
Soto R. A comparison of bispectral index and entropy or how to misinterpret both.
Anesth Analg,2005,100:1059-1061
|
CSCD被引
7
次
|
|
|
|
8.
Wheeler P. Response entropy increases during painful stimulation.
J Neurosurg Anesthesiol,2005,17:86-90
|
CSCD被引
7
次
|
|
|
|
9.
Vanluchene A L. Spectral entropy as an electroencephalographic measure of anesthetic drug effect: a comparison with bispectral index and processed midlatency auditory evoked response.
Anesthesiology,2004,101:34-42
|
CSCD被引
10
次
|
|
|
|
10.
Vakkuri A. Time-frequency balanced spectral entropy as a measure of anesthetic drug effect in central nervous system during sevoflurane, propofol, and thiopental anesthesia.
Acta Anaesthesiol Scand,2004,48:145-153
|
CSCD被引
21
次
|
|
|
|
11.
Ellerkmann R K. Spectral entropy and bispectral index as measures of the electroencephalographic effects of sevoflurane.
Anesthesiology,2004,101:1275-1282
|
CSCD被引
14
次
|
|
|
|
12.
Messner M. The bispectral index declines during neuromuscular block in fully awake persons.
Anesth Analg,2003,97:488-491
|
CSCD被引
11
次
|
|
|
|
13.
Nasraway SS Jr. How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study.
Crit Care Med,2002,30:1483-1487
|
CSCD被引
2
次
|
|
|
|
14.
Vivien B. Overestimation of Bispectral Index in sedated intensive care unit patients revealed by administration of muscle relaxant.
Anesthesiology,2003,99:9-17
|
CSCD被引
8
次
|
|
|
|
15.
Dahaba A A. The effect of different stages of neuromuscular block on the bispectral index and the bispectral index-XP under remifentanil/propofol anesthesia.
Anesth Analg,2004,99:781-787
|
CSCD被引
4
次
|
|
|
|
16.
Johansen J W. Development and clinical application of electroencephalographic bispectrum monitoring.
Anesthesiology,2000,93:1336-1344
|
CSCD被引
20
次
|
|
|
|
17.
Liu N. The influence of a muscle relaxant bolus on bispectral and Datex-Ohmeda entropy values during propofol-remifentanil induced loss of consiousness.
Anesth Analg,2005,101:1713-1718
|
CSCD被引
12
次
|
|
|
|
18.
Rampil I J. A primer for EEG signal processing in anesthesia.
Anesthesiology,1998,89:980-1002
|
CSCD被引
31
次
|
|
|
|
19.
Dierckens E. Is entropy a monitor for the guidance of intraoperative analgesia?.
Ann Fr Anesth Reanim,2007,26:113-118
|
CSCD被引
2
次
|
|
|
|
20.
Barth L. Paradoxical interaction between halothane and pancuronium.
Anaesthesia,1973,28:514-520
|
CSCD被引
1
次
|
|
|
|
|