双贴合无光焦度校正板在双球面镜次镜后的系统的像差特性研究
The Aberration Characteristics Analysis of A Two-sphere System with A Two-lens Zero-power Corrector Behind the Secondary Mirror

查看参考文献15篇

何宗平 1   张权 2   胡明勇 3  
文摘 讨论了双贴合无光焦度校正板放在次镜后的双反射球面系统。根据像差理论分析了消像差的条件,研究了主镜的相对孔径变化、校正板在次镜后的位置变化以及无光焦度校正板的正负透镜的不同组合形式对系统高级残余像兰的影响。结果表明:当主镜的相对孔径增加或校正板靠近次镜时,系统的残余像差增加;无论校正板的第一个透镜是正透镜还是负透镜,系统在某一光焦度处残余像差最小,并且靠近次镜的透镜最好采用负透镜。
其他语种文摘 A two-sphere system with a two-lens zero-power corrector placed behind the secondary mirror was discussed. According to third-order aberration theory, the conditions of the absence of aberrations were analyzed, and the influences to the remaining high order aberrations of the system caused by thechange of the relative aperture of the primary mirror, the position of the corrector and the different combination of the positive and negative lens in the corrector were investigated. The results show that the remaining aberrations will increase if the relative aperture of the primary increase or if the corrector approaches the secondary mirror. No matter the first lens of the corrector is positive or negative, there would be a particular optical power which causes smallest remaining aberrations, and it's better to use a negative lens near the secondary mirror.
来源 光子学报 ,2006,35(3):435-438 【核心库】
关键词 三级像差理论 ; 无光焦度校正板 ; 像差平衡 ; 两镜系统
地址

1. 合肥运涛光电科技有限公司, 合肥, 230031  

2. 中国科技大学天文与应用物理系, 合肥, 230026  

3. 中国科学院安徽光学精密机械研究所, 合肥, 230031

语种 中文
文献类型 研究性论文
ISSN 1004-4213
学科 物理学
文献收藏号 CSCD:2339739

参考文献 共 15 共1页

1.  Rogers A. On the construction of large achromatic telescopes. Memoirs of the Astronomical Society of London,1829,32(6):229-233 CSCD被引 1    
2.  Ross F. Lens system for correcting coma or mirrors. Astrophsics Journal,1935,81(2):156-159 CSCD被引 1    
3.  Wynne C. Field correctors for large telescopes. Applied Optics,1965,4(9):1185-1189 CSCD被引 1    
4.  Gascoigne S. Recent advances in astronomical optics. Applied Optics,1973,12(7):1419-1423 CSCD被引 1    
5.  Meinel A. Aspheric field correctors for large telescopes. Astronomical Journal,1953,118(6):335-339 CSCD被引 1    
6.  Schulte D. Prime focus correctors involving aspherics. Applied Optics,1966,5(2):313-316 CSCD被引 1    
7.  Wynne C. Field correctors for astronomical telescopes. Progress in Optics,1972:139-142 CSCD被引 1    
8.  Schulte D. Anastigmatic cassegrain type telescope. Applied Optics,1966,5(2):309-313 CSCD被引 1    
9.  Rosin S. Richey-chretien corrector system. Applied Optics,1966,5(4):675-680 CSCD被引 2    
10.  Wilson R. Corrector system for cassegrain telescope. Applied Optics,1968,7(2):253-259 CSCD被引 1    
11.  Rosin S. Corrected cassegrain system. Applied Optics,1964,3(1):151-155 CSCD被引 4    
12.  何宗平. 双透镜无光焦度校正板在单一反射镜后的光学系统的像差特性分析. 量子电子学报,2003,20(5):531-536 CSCD被引 1    
13.  何宗平. 双透镜无光焦度校正板在单反镜前的系统研究. 光子学报,2004,33(3):346-349 CSCD被引 2    
14.  潘君华. 光学非球面的设计、加工与检验. 光学非球面的设计、加工与检验,1994:12-15 CSCD被引 2    
15.  张以谟. 应用光学. 应用光学,1982:510-513 CSCD被引 3    
引证文献 1

1 肖光辉 无光焦度校正板在主镜后的牛顿光学系统的设计 光子学报,2009,38(3):610-615
CSCD被引 0 次

显示所有1篇文献

论文科学数据集
PlumX Metrics
相关文献

 作者相关
 关键词相关
 参考文献相关

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心