A Calculation of Steady Pressure Drop and an Analysis of HT-7U CICC

查看参考文献3篇

Wu Yu  
文摘 Under the condition of steady,the pressure drop of coolant is mainly caused by friction along the cable.in the CICC(cable-in-conduit-conductor).helium flow within the conductor consists of two parallel interconnected tubes.The velocity distribution has some differece between the central channel and conductor space.The region of Reynolds number is from 10~3 to 10~6.This paper describes the calculation of pressure drop of HT-7U CICC at various mass flows.It is assumed that the coolant flows in two parallel,rough tudes during the caclulation.
来源 Plasma Science & Technology ,2002,4(4):1395-1398 【核心库】
DOI 10.1088/1009-0630/4/4/009
关键词 HT-7U tokamak ; cable-in-conduit-conductor ; steady pressre drop ; calculation and analysis
地址

Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031

语种 英文
文献类型 研究性论文
ISSN 1009-0630
学科 物理学
基金 国家“九五”重大科学工程项目
文献收藏号 CSCD:1362109