双差分激光雷达-一组可以提高臭氧测量精度的波长
Comparison of tropospheric ozone measurements between three-wavelength dual-DIAL and two-wavelength DIAL method

查看参考文献9篇

文摘 模拟了气溶胶影响三波长双差分(266-289-308 nm)方法和双波长差分(266-289 nm和266-308 nm)方法测量对流层臭氧的误差,并在合肥测量了对流层2~3.6 km高度的臭氧分布。结果表明,三波长双差分方法比常规的双波长差分方法能更有效地克服气溶胶的影响,三波长差分测量的结果比常规的双波长差分的结果更精确。同时还揭示了气溶胶影响双波长差分方法测量臭氧的规律。模拟结论与测量结果是一致的。
其他语种文摘 In this paper the effects of aerosol on tropospheric ozone measurements by three-wavelength (266-289-308 nm) dual differential absorption lidar (DIAL) and two-wavelength (266-289 nm and 266-308 nm) differential absorption lidar are simulated and ozone profiles from 2 to 3.6 km altitude at Hefei are measured. Results show that the the three-wavelength dual-DIAL method is more effective to reduce the effects of aerosol than the two-wavelength DIAL method, and more accurate ozone density can be obtained by the three-wavelength dual-DIAL method. In the meantime, the laws of aerosol effects ware found on DIAL measurements in tropospheric ozone. Measurement results show great agreement with simulation conclusions.
来源 气象学报 ,2002,60(4):486-493 【核心库】
关键词 双波长差分 ; 三波长双差分 ; 气溶胶 ; 臭氧
地址

中国科学院安徽光学精密机械研究所, 大气光学国家重点实验室, 合肥, 230031

语种 中文
文献类型 研究性论文
ISSN 0577-6619
学科 大气科学(气象学)
基金 国家863计划 ;  国家自然科学基金
文献收藏号 CSCD:1140832

参考文献 共 9 共1页

1.  ScienceChina 中国科学文献服务系统

您还没有权限

 


请您 返回ScienceChina—中国科学文献服务系统首页重新检索,如果您在使用ScienceChina—中国科学文献服务系统遇到问题。

销售咨询联系:

北京中科进出口有限责任公司

联系电话: (010) 84039345-635

电子邮件:chuw@bjzhongke.com.cn

联系地址:北京市东城区安定门外大街138号皇城国际大厦B座801 100011

服务咨询联系:

中国科学院文献情报中心

联系电话: (010) 82627496

传 真:(010) 82627496

电子邮件:cscd@mail.las.ac.cn

联系地址:北京市 海淀区 北四环西路33号 100190

版权所有 ©2008 中国科学院文献情报中心 制作维护:中国科学院文献情报中心
地址:北京中关村北四环西路33号 邮政编码:100190 联系电话:(010)82627496 E-mail:cscd@mail.las.ac.cn 京ICP备05002861号-4 | 京公网安备11010802043238号